Velvet Skin Intra Plus guarantees to the patient notable improvements related to skin rejuvenation, body reshaping and re-toning, thanks to the use of innovative technologies like radiofrequency, electroporation, fractional radiofrequency, radioscalpel and intradermal radiofrequency.
wrinkles, micro-wrinkles, acne, muscular hypotonia, cellulite, skin relaxation, localised adiposity, stretch marks, periocular wrinkles, skin texture imperfections, skin dehydration, chin and cheeks laxity;
Physiotherapy use: arthrosis, low back pain, sciatica, and other osteoarticular, ligamentous and tendinous pathologies.
Radiofrequency
RF is a non-invasive method that efficiently counters skin ageing signs and allows to obtain a long lasting improvement of the skin, both for face and body.
The device implements an applicator able to induce a dermal temperature increase, that stimulates the production of new collagen granting, so, regenerative effects on the treated zone will be visible since the firsts treatments
• No-pain treatment
• The treatment duration is about 30-40 minutes, and the patient feels a pleasant heat perception
• Tissue reshaping and tone will be visible since the first treatment
• Results will be long lasting, also when the treatments will end
• In physiotherapy it induces an increase of blood circulation and vasodilation on the target area. It is possible to treat arthrosis, low back pain, sciatica, and other osteoarticular, ligamentous and tendinous pathologies; the tissue stimulation guarantees symptomatology decreases since the first treatment.
Electroporation
It is a non-invasive and painless technology that could be defined as “virtual syringe”. A particular electromagnetic impulse allows the transdermal absorption of active ingredients without needles, granting high concentration and effectiveness only on the target areas.
Fractional Radiofrequency
The fractional mode is so defined, because it works selectively on a determined area, starting a mechanism that activates the cellular metabolism without side effects, and working directly on epidermis with a repair action.
Radioscalpel
It is a technology indicated for micro-surgery methods, related to delete hyper-pigmentation and superficial imperfections.
Intradermal Radiofrequency
It is an innovative and painless method that allows to work below the wrinkle, inducing a “filler effect” without inoculation of exogenous substances.
• Feedback of the impedance of the treatment area to adapt the treatment parameters to the individual conditions of the patient.
• Possibility of setting two frequencies through the software: 500 kHz for pathologies at a greater depth and 1 MHz for more superficial pathologies.
• Possibility of setting monopolar or bipolar mode on large areas through the software without changing hand piece.
• Possibility of setting capacitive or resistive mode through the software without changing hand pieces.
• Capacitive hand pieces without epoxy coating.
• Pre-set programmes according to pathologies and areas.
• Possibility of sterilising the hand piece for electroporation in autoclave.
• All of the parameters are displayed on a 10” colour touch screen.
• The software is designed according to the Friendly Human-Machine Interface [FHMI] concept to make it intuitive and easy to use.
– Power supply 100÷240 V, 50÷60 Hz
– Max power consumption 450 W
– Electrical safety class II BF
– Protection rating IP IP40
– Max RF output power 150 W @ 50 ohm
– RF emission frequency 500 kPlz, 1000 kHz settable from software
– Type of emission Capacitive/Resistive
– Monopolar / Bipolar / Fractional / Radio scalpel / intradermal RF functions
– Max electroporation voltage 120 V @ 1000 ohm
– Electroporation impulse freq. 1÷3000 Hz, settable from software
– Complex electroporation wave shape, settable from software
– 10.1″ colour touch screen with embedded PC
– Operating temperature 0÷40 °C
– Operating humidity 30÷75% without condensation
– Dimensions L 45 x H 96 x D 41 cm
– Weight 7 kg
N.01 power cable
N.01 footswitch
N.01 elastic band
N.01 monopolar face and physiotherapy RF transducer
N.02 face electrodes (size 10mm-25mm)
N.01 plexiglas facial electrode case
N.01 mono and bipolar body and physiotherapy RF transducer
N.01 steel plate
N.01 facial bipolar RF transducer with 2 retractable tips
N.01 medical electroporation transducer
N.01 buckskin plate for electroporation
N.03 5 ml Pic syringes
N.01 4-needle fractional transducer
N.01 radio scalpel transducer with loop
N.01 intra needle connector
N.03 needles RF intra (36mm-45mm-50mm) sterile and disposable
N.01 RF and electroporation cable kit
or call the toll-free number
Equipment certified in accordance with Directive 2007/47/EC Corrective Directive 93/42/EC
Top Quality Group reserves the right to change the above information without prior notice and, in any case, these information are not valid for contractual purposes