Diatherapy is the device that is designed and produced in Italy that bases its effectiveness on the synergy of innovative technologies, such as Capacitive/resistive diathermy, Glove conductive electrodes and Electroporation. The equipment, designed according to the latest technical and scientific knowledge, allows effective and non-invasive treatment of several physiotherapy indications of the whole body.
OSTEO-CARTILAGINOUS PATHOLOGIES MUSCULAR PATHOLOGIES TENDONS PATHOLOGIES SEROUS BURSA AND BANDS NEURAL PATHOLOGIES
DIATHERMY This avails of the therapeutic principle based on the induction of heat for a certain pre-established region of the human body. The “heating-energy” is not applied from the outside, but it causes an “appropriated bio-physic condition” aimed at inducing endogenous heat. ELECTROPORATION This innovative method makes it possible to transdermally transfer allopathic, homeopathic, homotoxicological active ingredients or platelet-rich plasma (PRP) in a non-invasive manner. The application of a particular electrical impulse on a biological surface causes a temporary increase in tissue permeability. This promotes the transcutaneous absorption of active ingredients with controlled release at a preset depth. GLOVE CONDUCTIVE ELECTRODES The technology uses special electro-conductive gloves in silver fibre, which are used to induce bio-stimulation with various physical and biological actions. The technology works by making parts of the body interact with electric currents having specific characteristics, suitably chosen on the basis of the physiological actions to be elicited. The main effects that can be obtained are: excitomotor, thermal, analgesic, trophic and chemical effects. Thanks to the synergy between technology and manual massage techniques, the Operator will be able to use their knowledge to “customize” the treatment, amplify its therapeutic performance and obtain an optimal result while reducing fatigue and physical effort.
Feedback of the impedance of the treatment area to adapt the treatment parameters to the individual conditions of the patient. Possibility of setting two frequencies through the software: 500 kHz for pathologies at a greater depth and 1 MHz for more superficial pathologies. Possibility of setting monopolar or bipolar mode on large areas through the software without changing transducer. Possibility of setting capacitive or resistive mode through the software without changing transducers. Capacitive transducers without epoxy coating. Possibility of sterilising the transducer for electroporation in autoclave. All of the parameters are displayed on a 10.1” colour touch screen and the software is designed according to the Friendly Human-Machine Interface [FHMI] concept to make it intuitive and easy to use.
Power supply 100÷240 V, 50÷60 Hz Max power consumption 450 W Electrical safety class II BF Protection rating IP IP40 Max RF output power 150 W @ 50 ohm RF emission frequency 500 kPlz, 1000 kHz settable from software Type of emission Capacitive/Resistive Monopolar / Bipolar functions Max electroporation voltage 120 V @ 1000 ohm Electroporation impulse freq. 1÷3000 Hz, settable from software Complex electroporation wave shape, settable from software 10.1″””” colour touch screen with embedded PC Operating temperature 0÷40 °C Operating humidity 30÷75% without condensation Dimensions L 45 x H 96 x D 41 cm Weight 7 kg
N.01 power cable N.01 small diathermy transducer N.01 large diathermy transducer N.01 head for bipolar diathermy N.03 heads for monopolar diathermy N.01 elastic band N.01 steel plate N.01 steel plate cable N.01 cable for electroporation N.02 face and body electroporation transducers with syringe N.01 medical electroporation transducer connection cable N.01 buckskin plate for electroporation N.02 connection cables for buckskin plate for electroporation N.01 electro-conductive glove
or call the toll-free number
Equipment certified in accordance with Directive 2007/47/EC Corrective Directive 93/42/EC